Short answer: check that every cable listed on the drawing has a result, tested to the agreed standard and category, with no unexplained failures.
Three kinds of testing
| Test | Shows |
|---|---|
| Continuity or wire map | Pins are connected correctly |
| Qualification | Whether the link can carry certain applications |
| Certification | Measured performance against a standard’s limits |
Ask which one is included. They are not equal.
What to check
- Cable identifier matches the label and drawing
- Selected standard and limit match your specification
- Permanent link or channel is stated
- Length is within limits
- Date, instrument and operator are recorded
- Marginal passes are explained
Common parameters
Reports show items such as insertion loss, near-end crosstalk and return loss. You need not calculate them, but a failure or marginal value should be investigated, often at a termination.
Fibre
Expect loss results per core and, where specified, traces from an optical time-domain reflectometer.
Keep the files
Store the report with drawings. It is the baseline when a fault appears later.
What we need from you
For cabling quotations, state the test level you require. See structured cabling and cabling products, then contact III.