Service · Integration

PA and Intercom Installation

Public address, background music, intercom and gate station installation by zone.

A public address system speaks to areas. An intercom lets two places talk to each other. III (Triple I) installs both for offices, factories, schools, mosques, shops and residential buildings.

What is included

  • Zone planning and speaker layout
  • Amplifier sizing against the speaker load
  • Cabling, rack build and connection
  • Paging microphones, music sources, schedules and volume controls
  • Priority settings, including muting on a fire signal
  • Video door phones, apartment intercom or IP door stations
  • Sound check, labelled drawings and user training

Equipment

We can supply TOA public address equipment. See PA and intercom products.

What affects the design?

  • Background noise level: a factory floor needs a different approach from an office
  • Ceiling height and type
  • Hard surfaces that cause echo and unclear speech
  • Number of zones and who may page each
  • Outdoor areas and weather exposure
  • Whether intercom calls should also ring office phones

Fire voice evacuation

A fire alarm voice evacuation system is built to fire standards with supervised circuits. That is RADS work, not an ordinary PA system. III’s PA can receive a fire signal to mute music. If one set of speakers must serve both purposes, RADS leads the design.

What is not included

Fire voice evacuation, room acoustic treatment, stage sound and lighting, and mains power works.

Testing

We check each zone and call point and note areas where speech is hard to understand, so that expectations are clear at handover.

What do you receive?

A zone drawing, speaker schedule, rack layout, labelled cables, priority settings and a short guide for the people who make announcements.

Allow for growth

Leave amplifier margin and spare zones if new floors or sheds are likely. Replacing an undersized amplifier later costs more than planning for it. Keep the labelled zone list beside the paging microphone.

What we need from you

  • Floor plans with ceiling types
  • List of zones and who may make announcements
  • Noisy areas and times
  • Rack location with power
  • For intercom, number of entrances, rooms or flats

Compare PA, intercom and telephone, see the PA and intercom solution and maintenance cover. Contact III for a survey and quotation.